To determine the model number, and generate a 'printer friendly' data sheet, we need to know the options you require.
Make your selections in the form then click the Get Part Number button.
The model number of the switch configured to your
specification is returned immediately. |
|
|
|
- N, HN, SC Connectors
- DC to 400 MHz
- Failsafe
- 1KW @ 30 MHz
- Vacuum
|
|
|
Specifications
|
2NV/2HNV/2SCV Series |
DC-30 MHz |
DC-50 MHz |
DC-100 MHz |
DC-400 MHz |
VSWR (max) |
1.05 |
1.06 |
1.08 |
1.10 |
Insertion Loss (dB max) |
0.07 |
0.08 |
0.09 |
0.10 |
Isolation (dB min) |
35 |
30 |
25 |
17 |
Actuator Current (Typical)
VDC |
Failsafe |
12 |
150mA |
28 |
84mA |
|
Weight (max.): 9 oz.
RF Impedance: 50 Ohms nominal
Operating Temp: -55°C to +85° ambient
Operating Life: 1,000,000 cycles min.
Switching Time: 15 mSec max.
Switching Sequence: Break Before Make
|
|
Note: If reduced coil current is
required, please contact factory. |
|
This can "hot" switch 1KW at 30 MHz with optional Tungsten contacts.
Note: "Hot" switching will greatly reduce the operating life of the switch.
|